Metal Working Fluids

 

CHECKING AND MONITORING SOLUBLE METALWORKING FLUIDS

CHECKING AND MONITORING CHART

Equipment

MIXER UNIT           REFRACTOMETER           PH PAPERS

Mixer Unit                     Refractometer                                                 PH Papers

What to do if Concentration is Too High 
• Adjust by adding water
• Check method of mixing and concentration of the mixer unit
• Check for excessive tramp oil 
• Re-check the concentration with refractometer

What to do if Concentration is Too Low 
• Adjust by adding a stronger mix of emulsion
• Check method of mixing and concentration of the mixer unit
• Re-check the concentration with refractometer

If the pH is Too Low 
• Adjust by adding a stronger mix of emulsion
• Tankside addition of biocide 
• Tankside addition of a high pH additive  
• Check for any possible contamination eg. cleaning fluid
• Do a dipslide to check for any micro-organism contamination   

If the pH is Too High (very rare) 
• Adjust by adding water
• pH should reduce naturally over time 
• Check for any possible contamination eg. cleaning fluid

6 Simple steps to manage coolant
1. Control Concentration
2. Remove all Swarf
3. Remove all Tramp oil
4. Manage machine Cleanliness
5. Circulate fluid daily
6. Top up daily

 

                    